Search This Blog

Monday, 24 February 2014

Introduction to the Research Tools Mind Map | ZENODO






HOME | CURRENT | ARCHIVES | FORUM



Research World, Volume 10, 2013

Online Version




Article A10.4



Introduction to the Research Tools Mind Map



Nader Ale Ebrahim

Research Support Unit, Centre of Research Services

Institute of Research Management and Monitoring (IPPP)

University of Malaya, Malaysia

aleebrahim[at]siswa.um.edu.my
Published Online: June 14, 2013


With the increasing use of information and
communications technology (ICT), researchers are able to use computer
software tools to find, organise, manipulate, analyse, and share
relevant information. However, there are hundreds of such tools to
select from, for various research-related uses. I have collected over
700 tools that can help researchers do their work efficiently. It is
assembled as an interactive Web-based mind map, titled
Research Tools, which is updated periodically. Created using the MindMeister software platform, Research Tools provides a convenient interface with zoom in/out, screen drag, and other user-friendly features.



Being a mind map, Research Tools
consists of a hierarchical set of nodes. It has four main nodes: (1)
Searching the literature, (2) Writing a paper, (3) Targeting suitable
journals, and (4) Enhancing visibility and impact, and six auxiliary
nodes. In the mind map, each parent node has several child nodes
associated with it, which can be accessed by clicking on the plus (+)
sign. Several free tools can be found in the child nodes. Some paid
tools are also included.




The four main nodes are described below,
listing some tools as examples. In the mind map, a green tick sign
indicates my preference for some tools. Users can access the tools by
clicking on the arrow sign that appears next to the tool title.




1. Searching the Literature



Tools under this node would assist
first-year research students and other early-stage researchers in
expanding their knowledge base and developing a research focus (Ale
Ebrahim, 2013). A sample of these tools is given below, grouped under
the specific purposes for which these tools might be used:




(a) Find keywords: Google AdWords, Google Trends, Springer Realtime, KwMap

(b) Develop a new keyword/phrase: Microsoft Adcenter Lab, Keyword Density Analyser, Free Keyword Tool

(c) Find research materials: Web of Science, Scopus®, ProQuest, Research Papers in Economics, Munich Personal RePEc Archive

(d) Evaluate a paper: Publish or Perish, Readermeter, Microsoft Academic Search

(e) Access databases: Social Science Research Network, Refdoc, iSEEK Education, Electrical Engineering & Computer Science

(f) Compare resources: Top 30 Web Tools to Search, 100 Useful Tips and Tools to Research the Deep Web

(g) Search visually: Kartoo, Redz



2. Writing a Paper



Several tools on research writing have been
assembled under this node. These tools help researchers in various
aspects of scientific and scholarly writing. Here is a sample of such
tools:




(a) Write and edit: Ginger, Spell Checker, Plagiarisma, Springer Exemplar

(b) Analyse and summarise texts: Smmry, Tools 4 Noobs, Free Summarizer

(c) Search desktop: DtSearch, Copernic Desktop Search

(d) Write collaboratively: Google Drive, Adobe acrobat professional

(e) Synthesise and visualise information: MindMeister, MindMaple, Text2mindmap

(f) Manage bibliographic data: Mendeley, EndNote, Zotero

(g) Build and share article collections: Bibliogo, WizFolio

(h) Detect and avoid plagiarism: Viper, The Plagiarism Checker, Turnitin, Paper Rater



3. Targeting Suitable Journals



Sometimes, researchers are not sure about
the journal they should target for publishing their research papers.
They would like to evaluate a journal’s visibility and credibility
before submitting their papers. Researchers can use a range of tools to
identify, assess, and select appropriate journals with a view to
enhancing their publication profile (Ale Ebrahim, 2010).




(a) Identify potential journals: Elsevier journal finder, JANE (from The Biosemantics Group), Springer journal advisor

(b) Detect relevant journals: Google Alerts, My Citation Alerts (from Web of Knowledge)

(c) Evaluate journal quality (impact factor and journal ranking): Journal Citation Report (Thomson Reuters), SJR (Scimago Lab), Eigenfactor® (University of Washington)



4. Enhancing Visibility and Impact



Publishing a research paper in a scholarly
journals is necessary but not sufficient for receiving citations in
future. We need to ensure that the paper is visible to the relevant
users and authors. There are tools that help in enhancing the visibility
and readership of research papers. Effective use of these tools can
result in increased citations and, thus, improve the h-index of the
author (h-index shows the author’s influence as a researcher, see Ale
Ebrahim, 2012; Aghaei Chadegani et al., 2013). Here is a sample of tools
to increase the visibility of one’s published papers:




(a) Create an online CV: ResearcherID, Publications List, ORCID, Google Scholar My Citations, A visual resume

(b) Create an online repository: CiteuLike, Getcited, PubZone, Social Science Open Access Repository, arXiv, HAL

(c) Share bookmarks: Diigo, Delicious, BibSonomy, ScienceWISE

(d) Publish and share information: Scribd, Docstoc®, figshare, Udemy

(e) Network with other researchers: ResearchGate, Academia, LinkedIn



5. Auxiliary Nodes



Research tools which could not be
categorised under the above four main nodes have been placed under six
auxiliary nodes. The auxiliary nodes are: Survey, Links, Keeping
up-to-date (Alert service), h-index, General, and Download. The tools
under these nodes can assist researchers in keeping track of their
research interest and activities in various ways.




(a) Stay current with research: Science direct alerts, MIT press, PubMed, Conference Alerts, WikiCFP

(b) Collect data: SurveyMonkey, Formsite, Survey share, Google Docs, eSurveysPro, Free Online Survey, KwikSurvey

(c) h-index: Prediction scientific h-index, Finding h-index in Web of Science, Optimizing your article for search engines, 10 Ways to Increase Usage and Citation of your Article Using Social Media



6. Conclusion



We can save plenty of research time by using
specific tools for specific purposes. This can facilitate quick
progress and early completion of research projects. In my experience,
research students who use these tools are able to complete their
literature review in less than 3 months.




Acknowledgement



Sincere thanks to Professor D. P. Dash for
his kind encouragement to write this article and his useful advice on
its organisation.




References



Aghaei Chadegani, A., Salehi, H., Yunus, M.
M., Farhadi, H., Fooladi, M., Farhadi, M., & Ale Ebrahim, N. (2013).
A comparison between two main academic literature collections: Web of
Science and Scopus databases.
Asian Social Science, 9(5), 18-26. Retrieved from http://dx.doi.org/10.5539/ass.v9n5p18



Ale Ebrahim, N. (2010). Target ISI journals: How to write/publish ISI papers [Presentation material]. Retrieved from http://works.bepress.com/aleebrahim/1/



Ale Ebrahim, N. (2012). Publication marketing tools: Enhancing research visibility and improving citations [Presentation material]. Retrieved from http://works.bepress.com/aleebrahim/64/



Ale Ebrahim, N. (2013). The effective use of research tools and resources. [Presentation material]. Retrieved from http://works.bepress.com/aleebrahim/73/





Suggested Citation: Ale Ebrahim, N. (2013). Introduction to the Research Tools mind map. Research World, 10, Article A10.4. Retrieved from http://www1.ximb.ac.in/RW.nsf/pages/A10.4







Copyleft The article may be used freely, for a noncommercial purpose, as long as the original source is properly acknowledged.


Xavier Institute of Management, Xavier Square, Bhubaneswar 751013, India

Research World (ISSN 0974-2379) http://www1.ximb.ac.in/RW.nsf/pages/Home


Introduction to the Research Tools Mind Map | ZENODO

Sunday, 23 February 2014

A framework for SaaS software packages evaluation and selection with virtual team and BOCR of analytic network process



Volume 67, Issue 1, January 2014, Pages 219-238

A framework for SaaS software packages evaluation and selection with virtual team and BOCR of analytic network process

School of Management and Economics, University of Electronic Science and Technology of China, Chengdu 610054, China




Abstract

Software packages evaluation and
selection is one of the most important activities encountered by
software as a service (SaaS) users in the high performance networked
computing environment, especially for the small or medium-sized
enterprises. In this paper, we propose a framework for SaaS software
packages evaluation and selection by combining the virtual team (VT) and
the BOCR (benefits, opportunities, costs, and risks) of the analytic
network process (ANP). Different from the traditional application of the
BOCR model of ANP, the proposed VT-BOCR model attempts to solve the
complex ANP model and overloaded pairwise comparisons by decomposing the
tasks to four parts, and performed by benefits virtual team (B-VT),
opportunities virtual team (O-VT), costs virtual team (C-VT), and risks
virtual team (R-VT) separately. The interactive networked media on
distributed environments not only makes the proposed framework possible
without the limitations of time, space, and human resources, but also
can take full advantage of the talent experts who are geographically
dispersed. The proposed framework also shows great potentials for aiding
practitioners and researchers concerned with the cloud services. ©
Springer Science+Business Media New York 2013.

Author keywords

ANP; BOCR; Distributed environments; Pairwise comparison; SaaS; Virtual team


ISSN: 09208542

CODEN: JOSUE
Source Type: Journal
Original language: English


DOI: 10.1007/s11227-013-0995-7
Document Type: Article


Scopus - Document details

[1402.3890] Power laws in citation distributions: Evidence from Scopus

Power laws in citation distributions: Evidence from Scopus

Modeling distributions of citations to scientific papers is crucial for
understanding how science develops. However, there is a considerable empirical
controversy on which statistical model fits the citation distributions best.
This paper is concerned with rigorous empirical detection of power-law
behaviour in the distribution of citations received by the most highly cited
scientific papers. We have used a large, novel data set on citations to
scientific papers published between 1998 and 2002 drawn from Scopus. The
power-law model is compared with a number of alternative models using a
likelihood ratio test. We have found that the power-law hypothesis is rejected
for around half of the Scopus fields of science. For these fields of science,
the Yule, power-law with exponential cut-off and log-normal distributions seem
to fit the data better than the pure power-law model. On the other hand, when
the power-law hypothesis is not rejected, it is usually empirically
indistinguishable from most of the alternative models. The pure power-law model
seems to be the best model only for the most highly cited papers in "Physics
and Astronomy". Overall, our results seem to support theories implying that the
most highly cited scientific papers follow the Yule, power-law with exponential
cut-off or log-normal distribution. Our findings suggest also that power laws
in citation distributions, when present, account only for a very small fraction
of the published papers (less than 1% for most of science fields) and that the
power-law scaling parameter (exponent) is substantially higher (from around 3.2
to around 4.7) than found in the older literature.
Comments:
18 pages, 1 figure
Subjects:
Digital Libraries (cs.DL); Physics and Society (physics.soc-ph); Applications (stat.AP)

Cite as:
arXiv:1402.3890 [cs.DL]
  (or arXiv:1402.3890v1 [cs.DL] for this version)

Submission history

From: Michal Brzezinski [view email]


[v1] Mon, 17 Feb 2014 05:17:29 GMT (60kb)


[1402.3890] Power laws in citation distributions: Evidence from Scopus

Transtibial prosthetic suspension: Less pistoning versus easy donning and doffing

Source: http://www.rehab.research.va.gov/jour/2012/499/gholizadeh499.html





Volume 49 Number 9, 2012

   Pages 1321 — 1330

Transtibial prosthetic suspension: Less pistoning versus easy donning and doffing

Hossein Gholizadeh, MEngSc;1* Noor Azuan Abu Osman, PhD;1 Arezoo Eshraghi, MSc;1 Sadeeq Ali, BSc;1 Stefan Karl Sævarsson, MSc;2 Wan Abu Bakar Wan Abas, PhD;1 Gholam Hossein Pirouzi, BSc1

1Department of Biomedical Engineering, Faculty of Engineering, University of Malaya, Kuala Lumpur, Malaysia; 2Department of Biomedical Engineering, University of Calgary, Calgary, Canada
Abstract—Poor suspension increases
slippage of the residual limb inside the socket during ambulation. The
main purpose of this article is to evaluate the pistoning at the
prosthetic liner-socket interface during gait and assess patients’
satisfaction with two different liners. Two prostheses with seal-in and
locking liners were fabricated for each of the 10 subjects with
transtibial amputation. The Vicon motion system was used to measure the
pistoning during gait. The subjects were also asked to complete a
Prosthesis Evaluation Questionnaire. The results revealed higher
pistoning inside the socket during gait with the locking liner than with
the seal-in liner (p < 0.05). The overall satisfaction with the locking liner was higher (p
< 0.05) because of the relative ease with which the patients could
don and doff the device. As such, pistoning may not be the main factor
that determines patients’ overall satisfaction with the prosthesis and
other factors may also contribute to comfort and satisfaction with
prostheses. The article also verifies the feasibility of the Vicon
motion system for measuring pistoning during gait.
Key words: amputation, gait, Iceross,
lower-limb amputation, motion analysis, pistoning, satisfaction,
suction, suspension, transtibial prosthesis.
*Address
all correspondence to Hossein Gholizadeh, MEngSc; Department of
Biomedical Engineering, Faculty of Engineering, University of Malaya,
50603, Kuala Lumpur, Malaysia; 603-7967-4581; fax: 603-7967-4579.

Email: gholizadeh@um.edu.my
The main roles of the suspension systems incorporated into
lower-limb prostheses are to hold the prosthesis on the residual limb
and to decrease the motion that takes place at the
bone-skin-liner-socket interface during ambulation (pistoning, vertical
movements within the socket) [1]. Effective suspension systems and
prosthetic components can improve a person with amputation’s gait and
decrease his or her energy expenditure [2–3]. Prosthetic limbs should
have an intimate fit with the residual limb in order to replace the lost
body part with a device that offers high levels of comfort and
satisfaction [3–6].

Individuals with amputation believe that both the suspension
method and the fitting of a prosthetic device have significant effects
on their overall satisfaction with the prosthesis [6–8]. Several
questionnaires have been developed and a number of prosthetics surveys
have been conducted to analyze patient satisfaction with prosthetic
devices. The majority of researchers prefer the Prosthesis Evaluation
Questionnaire (PEQ) as a means of evaluating differences in function,
performance, and satisfaction between the different components or
techniques of prosthetics fabrication and adjustment (Appendix, available online only) Good reliability and validity have been reported for the PEQ [9–11].

Evidence shows that silicone liners are preferred by many
people with lower-limb amputation because they offer enhanced suspension
and fit within the socket as well as improved function [3,7–8,12].
Previous research on the silicone liners has found that patient comfort
and satisfaction are particularly higher in contrast with other
suspension systems, such as the belt for patellar tendon bearing socket
[3,8,12]. Silicone liners are believed to be more effective in
controlling the pistoning within the prosthetic socket than polyethylene
foam (pelite) liners. Pistoning at the socket-liner interface is said
to be lower with silicone liners (1–5 mm) than with pelite liners
(6.0–41.7 mm) [13–21].

Based on the literature, the pistoning is correlated with the
prosthetic suspension system and fit [15]. Thus, both clinicians and
researchers should be able to determine the quality of suspension and
prevent the negative effects of pistoning (such as gait deviation, skin
breakdown, and discomfort) by pistoning measurement [13–22].

A number of methods exist to measure the pistoning of various
interfaces within the socket (liner-socket) or the residual limb
(bone-soft tissue). These include X-ray [12,20,23–25], spiral
computerized tomography [26], and photoelectric sensors [22]. These
measurement methods are mostly useful for measuring the bone movement
inside the socket. Recently, two new methods were introduced for the
liner-socket interface in transtibial prostheses: a photographic method
and a motion analysis system [16–19]. The literature review revealed
that the majority of researchers measured the pistoning during quiet
standing (static) and only a few had evaluated the pistoning that
occurred inside the socket during gait (dynamic) [15].

A previous study by Gholizadeh et al. revealed low levels of
pistoning for the seal-in suspension (Seal-In X5 liner, Össur;
Reykjavik, Iceland) than the locking system (Dermo liner, Össur) during
standing [16]. The findings of that study motivated this current
research and prompted investigation on the effects of these suspension
systems during gait along with patient satisfaction. To our knowledge,
no study has previously compared the quality of suspension systems
during gait and the associated levels of patient satisfaction.

Ten subjects with unilateral transtibial amputation
participated in this study. We determined the participants’ mobility
grade based on the guidelines of the American Academy of Orthotists
& Prosthetists [27]. Table 1 lists subject characteristics.


Table 1. 
*Inferior edge of patella to distal end of residual limb.
†Based
on American Academy of Orthotists & Prosthetists scale. K2 =
Patient has ability or potential for ambulation with ability to traverse
low-level environmental barriers such as curbs, stairs, or uneven
surfaces—a typical community ambulator. K3 = Patient has ability or
potential for ambulation with variable cadence—a typical community
ambulator with ability to traverse most environmental barriers and may
have vacation, therapeutic, or exercise activity that demands prosthetic
use beyond simple locomotion.
In order to be eligible for the study, subjects with
transtibial amputation were required to be unilateral, without pain or
ulcer on the residual limb, and with a residual-limb length not less
than 13 cm. Furthermore, they could not have volume fluctuation in the
residual limb, could not depend on assistive devices such as a cane or
crutches for ambulation, and had to have good upper-limb strength.

Two transtibial prostheses (Figure 1)
were manufactured for each subject. Two different suspension systems
were used: Seal-In X5 liner with valve (Icelock Expulsion Valve 551,
Össur) and Dermo liner with shuttle lock (Icelock Clutch 4H 214, Össur).
All prosthetic feet were Flex-Foot Talux (Össur) [16,18].


Figure 1. Transtibial suspension systems: (a) Seal-In X5 liner (Össur; Reykjavik, Iceland) with transparent socket and valve and (b) Dermo liner (Össur) with transparent socket and shuttle lock.

Figure 1.
Transtibial suspension systems: (a) Seal-In X5 liner (Össur; Reykjavik, Iceland) with transparent socket and valve and (b) Dermo liner (Össur) with transparent socket and shuttle lock.
Click Image to Enlarge. View as PowerPoint Slide
One of the researchers (registered prosthetist) designed, fit,
and aligned all the prosthetic limbs. Two separate total surface bearing
sockets were fabricated individually for each of the two liners that
were used in the study. Transparent thermoplastic material (NorthPlex 12
mm, North Sea Plastics Ltd; Glasgow, United Kingdom) enabled us to
check the socket fit. The subjects attended a gait training session in
the Brace and Limb Laboratory (Department of Biomedical Engineering,
University of Malaya, Malaysia).

The prosthetist ensured that there was no gait abnormality and
that the fit of the prosthetic sockets was satisfactory. We determined
prosthetic alignment through bench, static (standing in an upright
position), and dynamic (during walking) alignment. All subjects had an
acclimation period of 4 weeks for each prosthetic device. To ensure
subject safety, one definite socket was also made for each liner type
for the 4-week acclimation period. Check sockets were used only during
the kinematic experiments.

Following the trial period, we performed pistoning evaluation
in the motion analysis laboratory with the Vicon 612 system using seven
MXF20 motion capture cameras (Vicon; Los Angeles, California), which is
believed to have an accuracy level of less than ±0.1 mm [28]. We adopted
a sampling rate of 200 Hz for the data collection. The signals from the
motion analysis system were filtered by a Butterworth filter (cutoff
frequency of 10 Hz).

We fixed 16 reflective markers to the subjects’ lower limbs in
accordance with the Helen Hayes marker set. The knee and tibia markers
for the prosthetic leg were located on the lateral proximal socket wall
and the lateral distal end of the socket, respectively (Figure 2). We placed two additional markers on the liner under the knee joint level (LLin1) and 5 cm below that (LLin2) [16].


Figure 2. Marker positions on socket (lateral proximal socket wall [LPS] and lateral distal end of socket [LDS]) and liner (LLin1 and LLin2).

Figure 2.
Marker
positions on socket (lateral proximal socket wall [LPS] and lateral
distal end of socket [LDS]) and liner (LLin1 and LLin2).
Click Image to Enlarge. View as PowerPoint Slide
Because knee joint movement could affect the actual pistoning
values, we positioned the additional markers (LLin1 and LLin2), aligned
by laser liner, on the liner below the knee joint. With the transparent
socket, the markers were visible through the hard socket and detectable
by the cameras [16]. By fixing the markers to one segment (the shank),
we avoided knee movements leading to unreal displacement.

The transparent socket could create some reflections that could
be mistakenly considered as markers, therefore we used paper tape
(except for the areas where additional markers were located) to mask the
socket wall [16]. Prior to the test, we asked subjects to walk in the
motion analysis laboratory in order to accustom themselves to the
environment. Afterward, the subjects walked at a self-selected speed on
an 8 m walkway. We recorded five successful trials per subject with each
type of liner. We considered a trial to be successful if the cameras
could capture all the markers. We could measure the pistoning by
analyzing the markers’ positions; however, in order to detect one gait
cycle in each trial, we also used two Kistler force plates. There was a 1
min rest interval between the trials. We used the distance between the
markers on the liner and on the socket to identify the piston motion.

The reproducibility of measurements was evaluated by
intraobserver intrasession, intraobserver intersession, and
interobserver intersession variabilities. Two observers performed the
experiments over two sessions with a 1 week interval.

Following the experiments, we asked the subjects to complete
one PEQ for each studied liner. We used some parts of the PEQ to
quantitatively assess patient satisfaction [10]. The PEQ consisted of
the following three ­sections:

•
Demographic data (sex, age, weight, height, time since amputation, and cause of amputation).
•
Satisfaction (fit,
donning and doffing, sitting, walking on level surface, walking on
unlevel ground, ascending and descending stairs, cosmesis, and overall
­satisfaction).
•
Problems (sweat, wound, skin irritation, pistoning, pain, swelling [edema], smell, and unwanted sounds).
We rated the responses on a scale from 0 to 100, where 0
indicated "dissatisfaction or extreme problems" with the system and 100
indicated "complete satisfaction or no problems."

We used SPSS 18.0 (IBM Corporation; Armonk, New York) for the data analyses, with p-values set at 0.05. A paired-samples t-test
compared the effects of the two different liners on pistoning during
each gait cycle. We divided the gait cycle (stance and swing) into eight
phases. We divided the stance phase by initial contact, loading
response, midstance, terminal stance, and preswing. Initial swing,
midswing, and terminal swing formed the swing phase of gait. In order to
analyze the data, we first calculated the peak pistoning that occurred
during each phase of one gait cycle for one gait trial of each subject.
Following that, we computed the average peak pistoning that occurred
across five successful gait trials. Finally, we found the overall
average of peak pistoning across the different phases of gait for all 10
subjects for the comparison between the liners.

The mean time since amputation was 7 years and all subjects had
undergone amputation at least 3 years prior to study participation. The
reproducibility of the measurements across the different trials of one
session and between two sessions by two observers was shown to be high.
The intraclass correlation coefficients of intraobserver intrasession,
intraobserver intersession, and interobserver intersession were 0.92,
0.87, and 0.79, respectively.

The results of the motion analysis revealed that the amount of
pistoning that occurred when the Seal-In X5 liner was used was
significantly less than the pistoning with the Dermo liner throughout
the gait cycle (p < 0.05),
with the exception of loading response (0.5 mm), midstance (0.0 mm) and
terminal stance (0.0 mm). Both liners exhibited no pistoning during
preswing (Table 2, Figures 3–4).


Figure 3. Sample pistoning patterns with Seal-In X5 liner (Össur; Reykjavik, Iceland) and Dermo liner (Össur) during one gait cycle for subjects (a) 2 and (b) 5.

Figure 3.
Sample pistoning patterns with Seal-In X5 liner (Össur; Reykjavik,
Iceland) and Dermo liner (Össur) during one gait cycle for subjects (a) 2 and (b) 5.
Click Image to Enlarge. View as PowerPoint Slide

Figure 4. Comparison of mean displacement in different phases of gait cycle (n = 10).

Figure 4.
Comparison of mean displacement in different phases of gait cycle (n = 10).
Click Image to Enlarge. View as PowerPoint Slide
During initial contact, the Dermo liner was displaced 5.1 ± 0.7
mm (mean ± standard deviation) within the socket. However, this value
decreased rapidly to 0.0 mm at the end of loading response and remained
the same until the initial swing. Only 1.9 ± 0.4 mm of pistoning was
found with the Seal-In X5 liner during initial contact. Maximum
displacements in 10 subjects were 5.4 ± 0.6 mm for the Dermo and 2.5 ±
0.4 mm for the Seal-In X5 liners during the initial swing.

The PEQ revealed that the subjects were overall more satisfied (p
< 0.05) with the Dermo liner than the Seal-In X5 liner.
Nevertheless, many of them mentioned increased levels of pain and
pistoning when using the Dermo liner. Donning and doffing the Seal-In X5
liner was more difficult, but the satisfaction with the socket fit was
higher (Table 3). The
participants also stated that the prosthesis with the Seal-In X5 liner
acted like a natural part of their body and that they did not experience
any traction at the end of the liner.


Table 3. 
p-Value
Mean†
p-Value
Pistoning Within Socket
0.04‡
Swelling (edema)
*Greater mean indicates higher satisfaction.
†Greater mean indicates less complaints/problems.
‡Statistically significant.
Selecting a suitable suspension system for individuals who have
undergone transtibial amputation is a critical issue in rehabilitation
[7,16,18]. In this study, we evaluated two different prosthetic
suspension systems in 10 subjects with transtibial amputation to compare
pistoning movement and patient satisfaction with the device during
ambulation. The Vicon motion system was introduced for the purpose of
evaluating pistoning during gait.

The literature review revealed that the majority of existing
research was based on pistoning measurement in the static position of
quiet standing as opposed to walking [15]. The complications of taking
such measurements during gait and concerns over subject safety by
exposure to X-ray hampered such practice [22]. A few studies attempted
to use videofluoroscopy [29], photoelectric sensors [22], or axial
movement detectors [30] to measure the pistoning that occurred during
ambulation. However, they were only able to measure vertical movement
between the pelite liner and socket [22,30]. Among them, only Sanders et
al. provided the value of the pistoning that occurred across different
phases of gait [22].

In this study, the Vicon motion system was shown to be an
efficient method of measuring the pistoning at the liner-socket
interface during the gait. It also offered a harmless method of
pistoning measurement [22]. However, it is unable to detect bone
displacement within the soft tissue.

This study showed that the Seal-In X5 liner helps to decrease
pistoning by developing suction against the socket wall. The resultant
suction ensures firm attachment between the liner and the socket wall.
The purpose of silicone liners is to provide enhanced suspension by
causing less pistoning within the prosthetic socket [3,8,12,15]. The
findings of this study support this statement because the pistoning
values with both Seal-In X5 and Dermo liners were lower than those found
with the polyethylene foam liners [22,29–30].

With the exception of the preswing phase, we found significant differences between the two liners during the gait cycle (p < 0.05) (Figures 3–4, Table 2).
These significant differences can be attributed to the different
elongation properties of the liners used [16,18]. The pistoning that
occurred during the initial swing might have been high as a result of
peak flexion in the knee joint.

Finally, as a result of centrifugal forces, the pistoning
increased between the liners and socket during the terminal swing. We
noted significant difference in pistoning between the studied liners
during this phase of the gait (p < 0.05), which can be associated with the firm attachment between the Seal-In X5 liner and the socket.

Prosthetic satisfaction is an issue influenced by several
factors. Prosthetic users require more time and energy to don and doff
the Seal-In X5 liner [16,18]. They also need lubricant sprays to
facilitate donning. Moreover, hand dexterity is more critical for
donning and doffing a Seal-In X5
liner than for the Dermo liner. All locking liners usually have an
umbrella-shaped feature at the distal part that is connected distally to
a pin. Weight bearing during ambulation over this rigid and small pin
may result in pain at the distal end of the residual limb [31].

The Seal-In X5 liner seems to resolve the so-called problem of
"milking" (distal tissue stretch caused by the pin and lock) [32]. This
milking phenomenon can also result in pain, particularly at the end of
the tibia and along the tibial crest. The subjects in the current study
had more pain with the pin and lock suspension (Dermo liner) than the
Seal-In X5 liner.

Little is known about the effects of different prosthetic
components and systems on patient satisfaction with prostheses.
Effortless donning and doffing does appear to have a positive effect on
satisfaction with a prosthesis [6]. The participants of this study were
mainly dissatisfied with the Seal-In X5 in terms of donning and doffing
and many of them specified that donning and doffing was significantly
easier with the Dermo liner than with the Seal-In X5 liner. As such, the
subjects stated a preference for this suspension system over the
Seal-In X5 liner for long-term use.

One limitation of this study was the small sample size,
particularly for the satisfaction survey. In addition to this, further
research is needed to compare more suspension alternatives in order to
provide a better guideline for suspension system selection. Future
research should also investigate and compare the effects of these
suspension systems on proprioception.

In conclusion, amputation rehabilitation is influenced by
appropriate choice of prosthetic components in accordance with the real
needs of the individual. We can infer from the results of this study
that the Seal-In X5 liner decreased the pistoning within the prosthetic
socket ­significantly, possibly as a result of the strong suction seal
between the liner and the socket. Nevertheless, the subjects had
difficulty with donning and doffing. We can therefore conclude that
pistoning may not be the main factor that determines subjects’ overall
satisfaction with the prosthesis.

The study introduced a new method for evaluating the pistoning
at the liner-socket interface in transtibial prostheses during gait. The
Vicon system has the potential to detect the pistoning during gait
while also offering a safer alternative to X-ray. Further studies are
needed to come to a "gold standard" for pistoning.

Study concept and design: H. Gholizadeh, N. A. Abu Osman,

A. ­Eshraghi, S. Ali, S. K. Sævarsson, W. A. B. Wan Abas.
Acquisition of data: H. Gholizadeh, A. Eshraghi.
Analysis and interpretation of data: H. Gholizadeh, N. A. Abu Osman, A. Eshraghi, S. Ali.
Drafting of manuscript: H. Gholizadeh, A. Eshraghi.
Critical revision of manuscript for important intellectual content: H. Gholizadeh, N. A. Abu Osman, A. Eshraghi, S. Ali, S. K. Sævarsson, W. A. B. Wan Abas.
Obtained funding: H. Gholizadeh, N. A. Abu Osman, S. K. Sævarsson.
Administrative, technical, or material support: N. A. Abu Osman, S. K. Sævarsson, G. H. Pirouzi.
Study supervision: N. A. Abu Osman, W. A. B. Wan Abas.
Financial Disclosures: The authors have declared that no competing interests exist.
Funding/Support:
This material was based on work supported by the Malaysia UM/MOHE/HIR
(grant D000014–16001) and the prosthetic components were donated by
Össur.
Additional Contributions: The authors would like to thank Mrs. Elham Sadat Yahyavi, Ms. Ása Guðlaug Lúðvíksdóttir, Dr. Nader Ale Ebrahim, and Mr. Scott Elliott for providing technical advice.
Institutional Review: The
ethical approval was granted from the University of Malaya Medical
Centre Ethics Committee. All subjects were asked to provide written
informed consent.
Participant Follow-Up: The authors do not plan to inform participants of the publication of this study due to a lack of contact information.
1.
Michael JW. Prosthetic suspensions and components. In: Smith DG, Michael JW, Bowker JH, editors. Atlas of amputations and limb deficiencies: Surgical, prosthetic, and rehabilitation principles. 3rd ed. Rosemont (IL): American Academy of Orthopaedic Surgeons; 2004. p. 409–25.
2.
Schmalz T, Blumentritt S, Jarasch R. Energy expenditure and
biomechanical characteristics of lower limb amputee gait: the influence
of prosthetic alignment and different prosthetic components. Gait
Posture. 2002;16(3):255–63.

[PMID:12443950]
http://dx.doi.org/10.1016/S0966-6362(02)00008-5
3.
Baars EC, Geertzen JH. Literature review of the possible advantages of silicon liner socket use in trans-tibial prostheses. Prosthet Orthot Int. 2005;29(1):27–37.

[PMID:16180375]
http://dx.doi.org/10.1080/17461550500069612
4.
Czerniecki JM, Gitter AJ. Gait analysis in the amputee: Has it helped the amputee or contributed to the development of improved prosthetic components? Gait Posture. 1996;4(3):258–68.

http://dx.doi.org/10.1016/0966-6362(96)01073-9
5.
Goh JC, Lee PV, Chong SY. Stump/socket pressure profiles of the pressure cast prosthetic socket. Clin Biomech (Bristol, Avon). 2003;18(3):237–43. [PMID:12620787]
http://dx.doi.org/10.1016/S0268-0033(02)00206-1
6.
Legro MW, Reiber G, del Aguila M, Ajax MJ, Boone DA, Larsen
JA, Smith DG, Sangeorzan B. Issues of importance reported by persons
with lower limb amputations and prostheses. J Rehabil Res Dev.
1999;36(3):155–63.

[PMID:10659798]
7.
Baars EC, Dijkstra PU, Geertzen JH. Skin problems of the stump and hand function in lower limb amputees: A historic cohort study. Prosthet Orthot Int. 2008;32(2):179–85.

[PMID:18569886]
http://dx.doi.org/10.1080/03093640802016456
9.
Berke GM, Fergason J, Milani JR, Hattingh J, McDowell M,
Nguyen V, Reiber GE. Comparison of satisfaction with current prosthetic
care in veterans and servicemembers from Vietnam and OIF/OEF conflicts
with major traumatic limb loss. J Rehabil Res Dev. 2010;47(4):361–71.

[PMID:20803404]
http://dx.doi.org/10.1682/JRRD.2009.12.0193
10.
Legro MW, Reiber GD, Smith DG, del Aguila M, Larsen J, Boone D. Prosthesis evaluation questionnaire for persons with lower limb amputations: assessing prosthesis-related quality of life. Arch Phys Med Rehabil. 1998;79(8):931–38.
[PMID:9710165]
http://dx.doi.org/10.1016/S0003-9993(98)90090-9
11.
Van de Weg FB, Van der Windt DA. A questionnaire survey
of the effect of different interface types on patient satisfaction and
perceived problems among trans-tibial amputees. Prosthet Orthot Int.
2005;29(3):231–39.

[PMID:16466153]
http://dx.doi.org/10.1080/03093640500199679
12.
Narita H, Yokogushi K, Shii S, Kakizawa M, Nosaka T. Suspension
effect and dynamic evaluation of the total surface bearing (TSB)
trans-tibial prosthesis: a comparison with the patellar tendon bearing
(PTB) trans-tibial prosthesis. Prosthet Orthot Int. 1997;21(3):175–78.

[PMID:9453088]
13.
Yiğiter K, Sener G, Bayar K. Comparison of the effects of patellar
tendon bearing and total surface bearing sockets on prosthetic fitting
and rehabilitation. Prosthet Orthot Int. 2002;26(3):206–12. [PMID:12562067]
http://dx.doi.org/10.1080/03093640208726649
14.
Commean PK, Smith KE, Vannier MW. Lower extremity residual limb slippage within the prosthesis. Arch Phys Med Rehabil. 1997;78(5):476–85. [PMID:9161365]
http://dx.doi.org/10.1016/S0003-9993(97)90160-X
15.
Eshraghi A, Osman NA, Gholizadeh H, Karimi MT, Ali S. Pistoning assessment in lower limb prosthetic sockets. Prosthet Orthot Int. 2012;36(1):15–24. [PMID:22269941]
http://dx.doi.org/10.1177/0309364611431625
16.
Gholizadeh H, Osman NA, Kamyab M, Eshraghi A, Abas WA,
Azam MN. Transtibial prosthetic socket pistoning: static evaluation of
Seal-In(®) X5 and Dermo(®) Liner using motion analysis system. Clin
Biomech (Bristol, Avon). 2012;27(1):34–39. [PMID:21794965]
http://dx.doi.org/10.1016/j.clinbiomech.2011.07.004
17.
Gholizadeh H, Abu Osman NA, Lúvíksdóttir Á, Eshraghi A,
Kamyab M, Wan Abas WA. A new approach for the pistoning measurement in
transtibial prosthesis. Prosthet Orthot Int. 2011;35(4):360–64. [PMID:21975850]
http://dx.doi.org/10.1177/0309364611423130
18.
Gholizadeh H, Abu Osman NA, Kamyab M, Eshraghi A, Lúvíksdóttir
AG, Wan Abas WA. Clinical evaluation of two prosthetic suspension
systems in a bilateral transtibial amputee. Am J Phys Med Rehabil.
2012;91(10):894–98.

[PMID:22173083]
http://dx.doi.org/10.1097/PHM.0b013e31823c74d7
19.
Gholizadeh H, Abu Osman NA, Lúðvíksdóttir ÁG, Kamyab
M, Eshraghi A, Ali S, Wan Abas WA. A new method for measuring pistoning
in lower limb prosthetic. Proceedings of 5th Kuala Lumpur International
Conference on Biomedical Engineering; 2011 Jun 20–23; Kuala Lumpur,
Malaysia. Berlin Heidelberg (Germany): Springer; 2011. p. 728–31.
20.
Lilja M, Johansson T, Öberg T. Movement of the tibial end in a PTB prosthesis socket: a sagittal X-ray study of the PTB prosthesis. Prosthet Orthot Int. 1993;17(1):21–26.

[PMID:8337097]
http://dx.doi.org/10.3109/03093649309164351
21.
Newton RL, Morgan D, Schreiber MH. Radiological evaluation of prosthetic fit in below-the-knee amputees. Skeletal Radiol. 1988;17(4):276–80. [PMID:3212490]
http://dx.doi.org/10.1007/BF00401811
22.
Sanders JE, Karchin A, Fergason JR, Sorenson EA. A noncontact sensor for measurement of distal residual-limb position during walking. J Rehabil Res Dev. 2006;43(4): 509–16. [PMID:17123190]
http://dx.doi.org/10.1682/JRRD.2004.11.0143
23.
Convery P, Murray KD. Ultrasound study of the motion of the residual femur within a trans-femoral socket during gait. Prosthet Orthot Int. 2000;24(3):226–32.

[PMID:11195358]
http://dx.doi.org/10.1080/03093640008726552
24.
Grevsten S, Erikson U. A roentgenological study of the stump-socket contact and skeletal displacement in the PTB-Suction Prosthesis. Ups J Med Sci. 1975;80(1):49–57.

[PMID:1145905]
http://dx.doi.org/10.3109/03009737509178991
25.
Papaioannou G, Mitrogiannis C, Nianios G, Fiedler G. Assessment of amputee socket-stump-residual bone kinematics during strenuous activities using Dynamic Roentgen Stereogrammetric Analysis. J Biomech. 2010;43(5):871–78.
[PMID:20047746]
http://dx.doi.org/10.1016/j.jbiomech.2009.11.013
26.
Madsen MT, Haller J, Commean PK, Vannier MW. A device
for applying static loads to prosthetic limbs of transtibial amputees
during spiral CT examination. J Rehabil Res Dev. 2000;37(4):383–87. [PMID:11028693]
27.
American Academy of Orthotists & Prosthetists. Medicare guideline forms: K-level determination (PSC044). Washington (DC): American Academy of Orthotists & Prosthetists; 2010.
29.
Bocobo CR, Castellote JM, MacKinnon D, Gabrielle-­Bergman
A. Videofluoroscopic evaluation of prosthetic fit and residual limbs
following transtibial amputation. J Rehabil Res Dev. 1998;35(1):6–13. [PMID:9505248]
30.
Wirta RW, Golbranson FL, Mason R, Calvo K. Analysis of below-knee suspension systems: effect on gait. J Rehabil Res Dev. 1990;27(4):385–96. [PMID:2089149]
http://dx.doi.org/10.1682/JRRD.1990.10.0385
31.
32.
Beil TL, Street GM. Comparison of interface pressures with pin and suction suspension systems. J Rehabil Res Dev. 2004;41(6A):821–28. [PMID:15685470]
http://dx.doi.org/10.1682/JRRD.2003.09.0146
This article and any supplementary material should be cited as follows:

Gholizadeh
H, Abu Osman NA, Eshraghi A, Ali S, Sævarsson SK, Wan Abas WA, Pirouzi
GH. Transtibial prosthetic suspension: Less pistoning versus easy
donning and doffing. J Rehabil Res Dev. 2012;49(9):1321–30.

http://dx.doi.org/10.1682/JRRD.2011.11.0221
ResearcherID: Hossein Gholizadeh, MEngSc: G-4838-2012; Noor A. Abu Osman, PhD: B-9265-2010; Arezoo Eshraghi, PhD: A-4405-2011
iThenticateCrossref
Go to TOP

Last Reviewed or Updated 

Tuesday, January 8, 2013 11:11 AM


Valid HTML 4.01 Transitional


Transtibial prosthetic suspension: Less pistoning versus easy donning and doffing